Every CVESearch/Get API key

CVE-2018-14801

In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018,...

6.2 Medium

CVE-2018-14801 is a medium vulnerability (CVSS 6.2) in Philips Pagewriter Tc10, Tc20, Tc30, Tc50, Tc70 Cardiographs, published August 22, 2018. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.41%, the 35th percentile. No source names a fixed version.

Severity
6.2 MediumCVSS 3.0, NVD
Exploit chance
0.41%EPSS, 35th percentile
Exploitation
None knownNot on CISA’s or ENISA’s lists
Fixed in
No fix listedNo source names one

Description

In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018, an attacker with both the superuser password and physical access can enter the superuser password that can be used to access and modify all settings on the device, as well as allow the user to reset existing passwords.

Attack profile

How easy it is to exploit

Attack vector
Physical
Complexity
Low
Privileges needed
High
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

0.41%Down 0.4 points since Apr 14, 2021
90%50%10%1%

Affected products

What each source reports

NVD Score used6.2

In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018, an attacker with both the superuser password and physical access can enter the superuser password that can be used to access and modify all settings on the device, as well as allow the user to reset existing passwords.

Record
CVE-2018-14801
CVSS 3.0
6.2 MediumCVSS:3.0/AV:P/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0
7.2 HighAV:L/AC:L/Au:N/C:C/I:C/A:C
Weakness
CWE-798
Updated
2026-11-02
CVE ListNo score

In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018, an attacker with both the superuser password and physical access can enter the superuser password that can be used to access and modify all settings on the device, as well as allow the user to reset existing passwords.

Record
CVE-2018-14801
Weakness
CWE-798
Updated
2026-11-02
EUVDEUVD-2018-6685No score

In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018, an attacker with both the superuser password and physical access can enter the superuser password that can be used to access and modify all settings on the device, as well as allow the user to reset existing passwords.

Record
EUVD-2018-6685
Updated
2026-11-03
GitHub AdvisoriesGHSA-v52g-8mcm-r52h6.2

In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018,...

In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018, an attacker with both the superuser password and physical access can enter the superuser password that can be used to access and modify all settings on the device, as well as allow the user to reset existing passwords.

Record
GHSA-v52g-8mcm-r52h
CVSS 3.0
6.2 MediumCVSS:3.0/AV:P/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-798
Updated
2026-11-02

History

History
RecordedChangedSources
facts
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

References

MoveEnter Open