Every CVESearch/Get API key

CVE-2014-5406

Hospira LifeCare PCA Infusion System

7.6

CVE-2014-5406 is a vulnerability (CVSS 7.6) in Hospira Lifecare Pca Infusion System, published July 6, 2015. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.22%, the 69th percentile. No source names a fixed version.

What does this mean?
Severity
7.6 CVSS 2.0, CVE List
Exploit chance
1.22%EPSS, 69th percentile
Exploitation
None knownNot on CISA’s or ENISA’s lists
Fixed in
No fix listedNo source names one

Description

The Hospira LifeCare PCA Infusion System before 7.0 does not validate network traffic associated with sending a (1) drug library, (2) software update, or (3) configuration change, which allows remote attackers to modify settings or medication data via packets on the (a) TELNET, (b) HTTP, (c) HTTPS, or (d) UPNP port. NOTE: this issue might overlap CVE-2015-3459.

Exploit likelihood

1.22%Up 0.1 points since Feb 4, 2022
90%50%10%1%

Affected products

What each source reports

CVE List Score used7.6

Hospira LifeCare PCA Infusion System

The Hospira LifeCare PCA Infusion System before 7.0 does not validate network traffic associated with sending a (1) drug library, (2) software update, or (3) configuration change, which allows remote attackers to modify settings or medication data via packets on the (a) TELNET, (b) HTTP, (c) HTTPS, or (d) UPNP port. NOTE: this issue might overlap CVE-2015-3459.

Record
CVE-2014-5406
CVSS 2.0
7.6 AV:N/AC:H/Au:N/C:C/I:C/A:C
Weakness
CWE-345
Updated
2026-11-02
EUVDEUVD-2014-52947.6

The Hospira LifeCare PCA Infusion System before 7.0 does not validate network traffic associated with sending a (1) drug library, (2) software update, or (3) configuration change, which allows remote attackers to modify settings or medication data via packets on the (a) TELNET, (b) HTTP, (c) HTTPS, or (d) UPNP port. NOTE: this issue might overlap CVE-2015-3459.

Record
EUVD-2014-5294
CVSS 2.0
7.6 HighAV:N/AC:H/Au:N/C:C/I:C/A:C
Updated
2026-11-02
GitHub AdvisoriesGHSA-vxf4-qh89-w2r6No score

The Hospira LifeCare PCA Infusion System before 7.0 does not validate network traffic associated...

The Hospira LifeCare PCA Infusion System before 7.0 does not validate network traffic associated with sending a (1) drug library, (2) software update, or (3) configuration change, which allows remote attackers to modify settings or medication data via packets on the (a) TELNET, (b) HTTP, (c) HTTPS, or (d) UPNP port. NOTE: this issue might overlap CVE-2015-3459.

Record
GHSA-vxf4-qh89-w2r6
Weakness
CWE-345
Updated
2026-11-02
NVD7.6

The Hospira LifeCare PCA Infusion System before 7.0 does not validate network traffic associated with sending a (1) drug library, (2) software update, or (3) configuration change, which allows remote attackers to modify settings or medication data via packets on the (a) TELNET, (b) HTTP, (c) HTTPS, or (d) UPNP port. NOTE: this issue might overlap CVE-2015-3459.

Record
CVE-2014-5406
CVSS 2.0
7.6 HighAV:N/AC:H/Au:N/C:C/I:C/A:C
CVSS 2.0
9.3 HighAV:N/AC:M/Au:N/C:C/I:C/A:C
Weakness
CWE-345
Updated
2026-11-02

History

History
RecordedChangedSources
facts
first indexedCVE List, EUVD, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

References

MoveEnter Open