CVE-2022-24118
Certain General Electric Renewable Energy products allow attackers to use a code to trigger a...
CVE-2022-24118 is a critical vulnerability (CVSS 9.1) in Ge Inet 900 Firmware, published December 26, 2022. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.67%, the 52nd percentile. No source names a fixed version.
- Severity
- 9.1 CriticalCVSS 3.1, NVD
- Exploit chance
- 0.67%EPSS, 52nd percentile
- Exploitation
- None knownNot on CISA’s or ENISA’s lists
- Fixed in
- No fix listedNo source names one
Description
Certain General Electric Renewable Energy products allow attackers to use a code to trigger a reboot into the factory default configuration. This affects iNET and iNET II before 8.3.0, SD before 6.4.7, TD220X before 2.0.16, and TD220MAX before 1.2.6.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- None
- Integrity
- High
- Availability
- High
Exploit likelihood
Affected products
What each source reports
NVD Score used 9.1
Certain General Electric Renewable Energy products allow attackers to use a code to trigger a reboot into the factory default configuration. This affects iNET and iNET II before 8.3.0, SD before 6.4.7, TD220X before 2.0.16, and TD220MAX before 1.2.6.
- Record
CVE-2022-24118- CVSS 3.1
- 9.1 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H - CVSS 3.1
- 9.1 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N - Weakness
- CWE-400
- Updated
- 2026-11-02
CVE List 9.1
Certain General Electric Renewable Energy products allow attackers to use a code to trigger a reboot into the factory default configuration. This affects iNET and iNET II before 8.3.0, SD before 6.4.7, TD220X before 2.0.16, and TD220MAX before 1.2.6.
- Record
CVE-2022-24118- CVSS 3.1
- 9.1 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N - Weakness
- CWE-400
- Updated
- 2026-11-02
EUVDEUVD-2022-29030 9.1
Certain General Electric Renewable Energy products allow attackers to use a code to trigger a reboot into the factory default configuration. This affects iNET and iNET II before 8.3.0, SD before 6.4.7, TD220X before 2.0.16, and TD220MAX before 1.2.6.
- Record
EUVD-2022-29030- CVSS 3.1
- 9.1 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N - Updated
- 2026-11-02
GitHub AdvisoriesGHSA-x7hm-4qr3-5hpg 9.1
Certain General Electric Renewable Energy products allow attackers to use a code to trigger a...
Certain General Electric Renewable Energy products allow attackers to use a code to trigger a reboot into the factory default configuration. This affects iNET and iNET II before 8.3.0, SD before 6.4.7, TD220X before 2.0.16, and TD220MAX before 1.2.6.
- Record
GHSA-x7hm-4qr3-5hpg- CVSS 3.1
- 9.1 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H - Weakness
- CWE-400
- Updated
- 2026-11-02
History
| Recorded | Changed | Sources |
|---|---|---|
| first indexed | CVE List, EUVD, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.