Skip to contentCodesys vulnerabilities
Products
Show 51 moreShow less
Newest
- codesys, codesys v2, plcwinnt +28 more +30 moreCODESYS V2 runtime: out-of-bounds read or write access may result in denial-of-serviceCVE-2021-345958.1 High
- codesys v2, plcwinnt, runtime toolkit +13 more +15 moreCODESYS V2 runtime: unauthenticated invalid requests may result in denial-of-serviceCVE-2021-345937.5 High
- codesys, codesys v2, wago 750-8202 firmware +26 more +28 moreCODESYS V2 web server: crafted requests could trigger a null pointer dereference (DoS)CVE-2021-34586EPSS 13.7%7.5 High
- codesys, codesys v2, wago 750-8202 firmware +26 more +28 moreCODESYS V2 web server: crafted requests could trigger a pointer dereference with an invalid address (DoS)CVE-2021-345857.5 High
- codesys, codesys v2, wago 750-8202 firmware +26 more +28 moreCODESYS V2 web server: crafted requests could trigger a buffer over-read (DoS)CVE-2021-345849.1 Critical
- codesys, codesys v2, wago 750-8202 firmware +26 more +28 moreCODESYS V2 web server: crafted requests could trigger a heap-based buffer overflow (DoS)CVE-2021-345837.5 High
- 3s-smart software solutions codesysAn unsafe deserialization vulnerability exists in the Engine.plugin ProfileInformation...CVE-2021-218698.8 High
- 3s-smart software solutions codesysA unsafe deserialization vulnerability exists in the ObjectManager.plugin Project...CVE-2021-218688.8 High
- 3s-smart software solutions codesysA unsafe deserialization vulnerability exists in the ObjectManager.plugin ObjectStream...CVE-2021-218678.8 High
- 3s-smart software solutions codesys, codesys development system +1 moreA unsafe deserialization vulnerability exists in the ComponentModel Profile.FromFile()...CVE-2021-218638.8 High
- codesys gatewayIn CODESYS Gateway V3 before 3.5.17.10, there is a NULL Pointer Dereference. Crafted...CVE-2021-367647.5 High
- codesys ethernetipIn CODESYS EtherNetIP before 4.1.0.0, specific EtherNet/IP requests may cause a null pointer...CVE-2021-367657.5 High
- codesys runtime toolkitAll versions of the CODESYS V3 Runtime Toolkit for VxWorks from version V3.5.8.0 and before...CVE-2021-334867.5 High
- codesys control, control rte, control runtime system toolkit +4 more +6 moreIn CODESYS V3 web server before 3.5.17.10, files or directories are accessible to External Parties.CVE-2021-367637.5 High
- codesys control, control rte, control runtime system toolkit +4 more +6 moreCODESYS Control Runtime system before 3.5.17.10 has a Heap-based Buffer Overflow.CVE-2021-334859.8 Critical
- 3s-smart software solutions codesys, codesys development system +1 moreA unsafe deserialization vulnerability exists in the ObjectManager.plugin ProfileInformation...CVE-2021-218668.8 High
- 3s-smart software solutions codesys, codesys development system +1 moreA unsafe deserialization vulnerability exists in the PackageManagement.plugin ExtensionMethods...CVE-2021-218658.8 High
- 3s-smart software solutions codesys, codesys development system +1 moreA unsafe deserialization vulnerability exists in the ComponentModel ComponentManager...CVE-2021-218647.8 High
- codesys plcwinnt, runtime toolkit, wago 750-8202 firmware +26 more +28 moreCODESYS V2 runtime system before 2.4.7.55 has Improper Input Validation.CVE-2021-301957.5 High
- codesys v2 runtime system sp, wago 750-8202 firmware, 750-8203 firmware +25 more +27 moreCODESYS V2 runtime system SP before 2.4.7.55 has a Stack-based Buffer Overflow.CVE-2021-301889.8 Critical
- codesys plcwinnt, runtime toolkit, wago 750-8202 firmware +26 more +28 moreCODESYS V2 runtime system SP before 2.4.7.55 has a Heap-based Buffer Overflow.CVE-2021-301867.5 High
- codesys v2 web server, wago 750-8202 firmware, 750-8203 firmware +25 more +27 moreCODESYS V2 Web-Server before 1.1.9.20 has an Out-of-bounds Read.CVE-2021-301949.1 Critical
- codesys v2 web server, wago 750-8202 firmware, 750-8203 firmware +25 more +27 moreCODESYS V2 Web-Server before 1.1.9.20 has an Out-of-bounds Write.CVE-2021-301939.8 Critical
- codesys v2 web server, wago 750-8202 firmware, 750-8203 firmware +25 more +27 moreCODESYS V2 Web-Server before 1.1.9.20 has an Improperly Implemented Security Check.CVE-2021-301929.8 Critical
- codesys v2 web server, wago 750-8202 firmware, 750-8203 firmware +25 more +27 moreCODESYS V2 Web-Server before 1.1.9.20 has a a Buffer Copy without Checking the Size of the Input.CVE-2021-301917.5 High
- codesys v2 web server, wago 750-8202 firmware, 750-8203 firmware +25 more +27 moreCODESYS V2 Web-Server before 1.1.9.20 has Improper Access Control.CVE-2021-301909.8 Critical
- codesys v2 web server, wago 750-8202 firmware, 750-8203 firmware +25 more +27 moreCODESYS V2 Web-Server before 1.1.9.20 has a Stack-based Buffer Overflow.CVE-2021-301899.8 Critical
- codesys runtime toolkit, wago 750-8202 firmware, 750-8203 firmware +25 more +27 moreCODESYS V2 runtime system SP before 2.4.7.55 has Improper Neutralization of Special Elements used...CVE-2021-301875.3 Medium
- codesys development systemThe Package Manager of CODESYS Development System 3 before 3.5.17.0 does not check the validity...CVE-2021-292407.8 High
- codesys control for beaglebone sl, control for empc-a\/imx6 sl, control for iot2000 sl +19 more +21 moreCODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send...CVE-2021-292427.3 High
- codesys development systemCODESYS Development System 3 before 3.5.17.0 displays or executes malicious documents or files...CVE-2021-292397.8 High
- codesys automation serverCODESYS Automation Server before 1.16.0 allows cross-site request forgery (CSRF).CVE-2021-292388.8 High
- codesys gateway, control for beaglebone sl, control for empc-a\/imx6 sl +8 more +10 moreCODESYS Gateway 3 before 3.5.17.0 has a NULL pointer dereference that may result in a denial of...CVE-2021-292417.5 High
- codesys control for beaglebone, control for empc-a\/imx6, control for iot2000 +13 more +15 moreCODESYS Control runtime system before 3.5.16.10 allows Uncontrolled Memory Allocation.CVE-2020-158067.5 High
- codesys development system, control for beaglebone, control for empc-a\/imx6 +9 more +11 moreAn issue was discovered in CODESYS Development System before 3.5.16.0. CODESYS WebVisu and...CVE-2020-120686.5 Medium
- codesys runtimeAn exploitable code execution vulnerability exists in the PLC_Task functionality of 3S-Smart...CVE-2020-60819.9 Critical
- codesysAn exploitable memory corruption vulnerability exists in the Name Service Client functionality of...CVE-2019-51057.5 High
- codesys control for beaglebone, control for empc-a\/imx6, control for iot2000 +11 more +13 moreCODESYS V3 web server before 3.5.15.40, as used in CODESYS Control runtime systems, has a buffer...CVE-2020-102459.8 Critical
- codesys gateway, hmi, control for beaglebone +12 more +14 moreCODESYS Control V3, Gateway V3, and HMI V3 before 3.5.15.30 allow uncontrolled memory allocation...CVE-2020-70526.5 Medium
- codesys plcwinnt, runtime toolkit, sp realtime nt +2 more3S-Smart CODESYS SP Realtime NT before V2.3.7.28, CODESYS Runtime Toolkit 32 bit full before V2.4...CVE-2019-197896.5 Medium
- codesys control for beaglebone, control for empc-a\/imx6, control for iot2000 +11 more +13 moreCODESYS 3 web server before 3.5.15.20, as distributed with CODESYS Control runtime systems, has a...CVE-2019-188589.8 Critical
- codesys, codesys eni server +1 more3S-Smart CODESYS V2.3 ENI server V3.2.2.23 has a Buffer Overflow.CVE-2019-162659.8 Critical
- codesys3S-Smart Software Solutions GmbH CODESYS V3 Library Manager, all versions prior to 3.5.15.0,...CVE-2019-135388.6 High
- gmbh 3s-smart software solutions gmbh codesys v3 opc ua server, codesys control for beaglebone, control for empc-a\/imx6 +8 more +10 more3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, all versions 3.5.11.0 to 3.5.15.0,...CVE-2019-135426.5 Medium
- codesys control for beaglebone, control for empc-a\/imx6, control for iot2000 +11 more +13 moreAn issue was discovered in 3S-Smart CODESYS before 3.5.15.0 . Crafted network packets cause the...CVE-2019-90097.5 High
- codesys control for beaglebone, control for empc-a\/imx6, control for iot2000 +7 more +9 moreAn issue was discovered in 3S-Smart CODESYS V3 through 3.5.12.30. A user with low privileges can...CVE-2019-90088.8 High
- codesys control for beaglebone, control for empc-a\/imx6, control for iot2000 +10 more +12 moreCODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially...CVE-2019-135489.8 Critical
- codesys control for beaglebone, control for empc-a\/imx6, control for iot2000 +10 more +12 moreCODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially...CVE-2019-135327.5 High
- codesys development system, gateway, control for beaglebone sl +7 more +9 moreAn issue was discovered in 3S-Smart CODESYS V3 products. A crafted communication request may...CVE-2019-90127.5 High
- codesys development system, gateway, control for beaglebone sl +7 more +9 moreAn issue was discovered in 3S-Smart CODESYS V3 products. The CODESYS Gateway does not correctly...CVE-2019-90109.8 Critical
- Show moreLoading…