CVE-2018-7851
CWE-119: Buffer errors vulnerability exists in Modicon M580 with firmware prior to V2.50, Modicon...
CWE-119: Buffer errors vulnerability exists in Modicon M580 with firmware prior to V2.50, Modicon M340 with firmware prior to V3.01, BMxCRA312xx with firmware prior to V2.40, All firmware versions of Modicon Premium and 140CRA312xxx when sending a specially crafted Modbus packet, which could cause a denial of service to the device that would force a restart to restore availability.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- Low
- User interaction
- None
What an attacker can affect
- Confidentiality
- None
- Integrity
- None
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
6.5
CWE-119: Buffer errors vulnerability exists in Modicon M580 with firmware prior to V2.50, Modicon M340 with firmware prior to V3.01, BMxCRA312xx with firmware prior to V2.40, All firmware versions of Modicon Premium and 140CRA312xxx when sending a specially crafted Modbus packet, which could cause a denial of service to the device that would force a restart to restore availability.
- Record
CVE-2018-7851- CVSS 3.1
- 6.5 Medium
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H - CVSS 2.0
- 6.8 Medium
AV:N/AC:L/Au:S/C:N/I:N/A:C - Weakness
- CWE-119
- Updated
- 2026-11-02
CVE List No score
CWE-119: Buffer errors vulnerability exists in Modicon M580 with firmware prior to V2.50, Modicon M340 with firmware prior to V3.01, BMxCRA312xx with firmware prior to V2.40, All firmware versions of Modicon Premium and 140CRA312xxx when sending a specially crafted Modbus packet, which could cause a denial of service to the device that would force a restart to restore availability.
- Record
CVE-2018-7851- Weakness
- CWE-119
- Updated
- 2026-11-02
EUVDEUVD-2018-19563 No score
CWE-119: Buffer errors vulnerability exists in Modicon M580 with firmware prior to V2.50, Modicon M340 with firmware prior to V3.01, BMxCRA312xx with firmware prior to V2.40, All firmware versions of Modicon Premium and 140CRA312xxx when sending a specially crafted Modbus packet, which could cause a denial of service to the device that would force a restart to restore availability.
- Record
EUVD-2018-19563- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-prwp-rh6x-cr5m
6.5
CWE-119: Buffer errors vulnerability exists in Modicon M580 with firmware prior to V2.50, Modicon...
CWE-119: Buffer errors vulnerability exists in Modicon M580 with firmware prior to V2.50, Modicon M340 with firmware prior to V3.01, BMxCRA312xx with firmware prior to V2.40, All firmware versions of Modicon Premium and 140CRA312xxx when sending a specially crafted Modbus packet, which could cause a denial of service to the device that would force a restart to restore availability.
- Record
GHSA-prwp-rh6x-cr5m- CVSS 3.1
- 6.5 Medium
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H - Weakness
- CWE-119
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2018-7851 is a medium vulnerability (CVSS 6.5) in Schneider-electric 140cra312xxx Firmware, published May 22, 2019. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.17%, the 67th percentile. No source names a fixed version.