Every CVE Search/ Get API key

CVE-2018-7851

CWE-119: Buffer errors vulnerability exists in Modicon M580 with firmware prior to V2.50, Modicon...

6.5 Medium

CWE-119: Buffer errors vulnerability exists in Modicon M580 with firmware prior to V2.50, Modicon M340 with firmware prior to V3.01, BMxCRA312xx with firmware prior to V2.40, All firmware versions of Modicon Premium and 140CRA312xxx when sending a specially crafted Modbus packet, which could cause a denial of service to the device that would force a restart to restore availability.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
Low
User interaction
None

What an attacker can affect

Confidentiality
None
Integrity
None
Availability
High

Exploit likelihood

1.17%Up 0.6 points since Apr 14, 2021
90%50%10%1%

What each source reports

NVD Score used 6.5

CWE-119: Buffer errors vulnerability exists in Modicon M580 with firmware prior to V2.50, Modicon M340 with firmware prior to V3.01, BMxCRA312xx with firmware prior to V2.40, All firmware versions of Modicon Premium and 140CRA312xxx when sending a specially crafted Modbus packet, which could cause a denial of service to the device that would force a restart to restore availability.

Record
CVE-2018-7851
CVSS 3.1
6.5 MediumCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
CVSS 2.0
6.8 MediumAV:N/AC:L/Au:S/C:N/I:N/A:C
Weakness
CWE-119
Updated
2026-11-02
CVE List No score

CWE-119: Buffer errors vulnerability exists in Modicon M580 with firmware prior to V2.50, Modicon M340 with firmware prior to V3.01, BMxCRA312xx with firmware prior to V2.40, All firmware versions of Modicon Premium and 140CRA312xxx when sending a specially crafted Modbus packet, which could cause a denial of service to the device that would force a restart to restore availability.

Record
CVE-2018-7851
Weakness
CWE-119
Updated
2026-11-02
EUVDEUVD-2018-19563 No score

CWE-119: Buffer errors vulnerability exists in Modicon M580 with firmware prior to V2.50, Modicon M340 with firmware prior to V3.01, BMxCRA312xx with firmware prior to V2.40, All firmware versions of Modicon Premium and 140CRA312xxx when sending a specially crafted Modbus packet, which could cause a denial of service to the device that would force a restart to restore availability.

Record
EUVD-2018-19563
Updated
2026-11-03
GitHub AdvisoriesGHSA-prwp-rh6x-cr5m 6.5

CWE-119: Buffer errors vulnerability exists in Modicon M580 with firmware prior to V2.50, Modicon...

CWE-119: Buffer errors vulnerability exists in Modicon M580 with firmware prior to V2.50, Modicon M340 with firmware prior to V3.01, BMxCRA312xx with firmware prior to V2.40, All firmware versions of Modicon Premium and 140CRA312xxx when sending a specially crafted Modbus packet, which could cause a denial of service to the device that would force a restart to restore availability.

Record
GHSA-prwp-rh6x-cr5m
CVSS 3.1
6.5 MediumCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Weakness
CWE-119
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2018-7851 is a medium vulnerability (CVSS 6.5) in Schneider-electric 140cra312xxx Firmware, published May 22, 2019. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.17%, the 67th percentile. No source names a fixed version.