Every CVE Search/ Get API key

CVE-2020-7381

Code Injection in Rapid7 Nexpose Installer

5.8 Medium

In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during a Security Console installation and any arbitrary code executable using the same file name.

Attack profile

How easy it is to exploit

Attack vector
Local
Complexity
High
Privileges needed
High
User interaction
Required

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
Low

Exploit likelihood

0.68%Up 0.3 points since Apr 14, 2021
90%50%10%1%

What each source reports

CVE List Score used 5.8

Code Injection in Rapid7 Nexpose Installer

In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during a Security Console installation and any arbitrary code executable using the same file name.

Record
CVE-2020-7381
CVSS 3.1
5.8 MediumCVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:L
Weakness
CWE-94
Updated
2026-11-02
EUVDEUVD-2020-28508 5.8

In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during a Security Console installation and any arbitrary code executable using the same file name.

Record
EUVD-2020-28508
CVSS 3.1
5.8 MediumCVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:L
Updated
2026-11-03
GitHub AdvisoriesGHSA-pcgq-484v-rqvh No score

In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable...

In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during a Security Console installation and any arbitrary code executable using the same file name.

Record
GHSA-pcgq-484v-rqvh
Updated
2026-11-02
NVD 5.8

In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during a Security Console installation and any arbitrary code executable using the same file name.

Record
CVE-2020-7381
CVSS 3.1
5.8 MediumCVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:L
CVSS 3.1
7.8 HighCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
CVSS 2.0
6.8 MediumAV:N/AC:M/Au:N/C:P/I:P/A:P
Weakness
CWE-94
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2020-7381 is a medium vulnerability (CVSS 5.8) in Rapid7 Nexpose, published September 3, 2020. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.68%, the 52nd percentile. No source names a fixed version.

References

MoveEnter Open