CVE-2020-7381
Code Injection in Rapid7 Nexpose Installer
In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during a Security Console installation and any arbitrary code executable using the same file name.
Attack profile
How easy it is to exploit
- Attack vector
- Local
- Complexity
- High
- Privileges needed
- High
- User interaction
- Required
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- Low
Exploit likelihood
What each source reports
CVE List Score used
5.8
Code Injection in Rapid7 Nexpose Installer
In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during a Security Console installation and any arbitrary code executable using the same file name.
- Record
CVE-2020-7381- CVSS 3.1
- 5.8 Medium
CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:L - Weakness
- CWE-94
- Updated
- 2026-11-02
EUVDEUVD-2020-28508
5.8
In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during a Security Console installation and any arbitrary code executable using the same file name.
- Record
EUVD-2020-28508- CVSS 3.1
- 5.8 Medium
CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:L - Updated
- 2026-11-03
GitHub AdvisoriesGHSA-pcgq-484v-rqvh No score
In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable...
In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during a Security Console installation and any arbitrary code executable using the same file name.
- Record
GHSA-pcgq-484v-rqvh- Updated
- 2026-11-02
NVD
5.8
In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during a Security Console installation and any arbitrary code executable using the same file name.
- Record
CVE-2020-7381- CVSS 3.1
- 5.8 Medium
CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:L - CVSS 3.1
- 7.8 High
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H - CVSS 2.0
- 6.8 Medium
AV:N/AC:M/Au:N/C:P/I:P/A:P - Weakness
- CWE-94
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2020-7381 is a medium vulnerability (CVSS 5.8) in Rapid7 Nexpose, published September 3, 2020. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.68%, the 52nd percentile. No source names a fixed version.