CVE-2023-5987
A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting)...
A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability that could cause a vulnerability leading to a cross site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing the injected payload.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- Required
What an attacker can affect
- Confidentiality
- Low
- Integrity
- Low
- Availability
- None
Exploit likelihood
What each source reports
CVE List Score used
6.1
A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability that could cause a vulnerability leading to a cross site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing the injected payload.
- Record
CVE-2023-5987- CVSS 3.1
- 6.1 Medium
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N - Weakness
- CWE-79
- Updated
- 2026-11-02
EUVDEUVD-2023-58254
6.1
A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability that could cause a vulnerability leading to a cross site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing the injected payload.
- Record
EUVD-2023-58254- CVSS 3.1
- 6.1 Medium
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N - Updated
- 2026-11-03
GitHub AdvisoriesGHSA-f85w-wprq-6vjg
6.1
A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting)...
A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability that could cause a vulnerability leading to a cross site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing the injected payload.
- Record
GHSA-f85w-wprq-6vjg- CVSS 3.1
- 6.1 Medium
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N - Weakness
- CWE-79
- Updated
- 2026-11-02
NVD
6.1
A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability that could cause a vulnerability leading to a cross site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing the injected payload.
- Record
CVE-2023-5987- CVSS 3.1
- 6.1 Medium
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N - Weakness
- CWE-79
- Updated
- 2026-11-02
Affected products
- schneider electric ecostruxure power monitoring expert (pme)
- schneider electric ecostruxure power operation (epo) – advanced reporting and dashboards module
- schneider electric ecostruxure power scada operation (pso) - advanced reporting and dashboards module
- schneider-electric ecostruxure power monitoring expert
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases, published | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2023-5987 is a medium vulnerability (CVSS 6.1) in Schneider Electric Ecostruxure Power Monitoring Expert (pme), published November 15, 2023. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.41%, the 35th percentile. No source names a fixed version.