Every CVE Search/ Get API key

CVE-2015-1014

A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file...

7.3 High

A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version.

Attack profile

How easy it is to exploit

Attack vector
Local
Complexity
Low
Privileges needed
Low
User interaction
Required

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

0.46%Down 0.6 points since Feb 4, 2022
90%50%10%1%

What each source reports

NVD Score used 7.3

A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version.

Record
CVE-2015-1014
CVSS 3.0
7.3 HighCVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
CVSS 2.0
4.4 MediumAV:L/AC:M/Au:N/C:P/I:P/A:P
Weakness
CWE-427
Updated
2026-11-02
CVE List No score

A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version.

Record
CVE-2015-1014
Weakness
CWE-427
Updated
2026-11-02
EUVDEUVD-2015-1158 No score

A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version.

Record
EUVD-2015-1158
Updated
2026-11-03
GitHub AdvisoriesGHSA-f7j5-fwrm-8242 7.3

A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file...

A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version.

Record
GHSA-f7j5-fwrm-8242
CVSS 3.0
7.3 HighCVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
Weakness
CWE-427
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2015-1014 is a high vulnerability (CVSS 7.3) in Schneider Electric Ofs V3.5, published March 25, 2019. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.46%, the 39th percentile. No source names a fixed version.

References

MoveEnter Open