Every CVE Search/ Get API key

CVE-2017-9864

** DISPUTED ** An issue was discovered in SMA Solar Technology products. An attacker can change...

7.5 HighDisputed

An issue was discovered in SMA Solar Technology products. An attacker can change the plant time even when not authenticated in any way. This changes the system time, possibly affecting lockout policies and random-number generators based on timestamps, and makes timestamps for data analysis unreliable. NOTE: the vendor reports that this is largely irrelevant because it only affects log-entry timestamps, and because the plant time would later be reset via NTP. (It has never been the case that a lockout policy or random-number generator was affected.) Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
None
Integrity
High
Availability
None

Exploit likelihood

1.51%Up 0.7 points since Apr 14, 2021
90%50%10%1%

What each source reports

NVD Score used 7.5

An issue was discovered in SMA Solar Technology products. An attacker can change the plant time even when not authenticated in any way. This changes the system time, possibly affecting lockout policies and random-number generators based on timestamps, and makes timestamps for data analysis unreliable. NOTE: the vendor reports that this is largely irrelevant because it only affects log-entry timestamps, and because the plant time would later be reset via NTP. (It has never been the case that a lockout policy or random-number generator was affected.) Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected

Record
CVE-2017-9864
CVSS 3.0
7.5 HighCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
CVSS 2.0
5.0 MediumAV:N/AC:L/Au:N/C:N/I:P/A:N
Updated
2026-11-02
CVE List No score

An issue was discovered in SMA Solar Technology products. An attacker can change the plant time even when not authenticated in any way. This changes the system time, possibly affecting lockout policies and random-number generators based on timestamps, and makes timestamps for data analysis unreliable. NOTE: the vendor reports that this is largely irrelevant because it only affects log-entry timestamps, and because the plant time would later be reset via NTP. (It has never been the case that a lockout policy or random-number generator was affected.) Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected

Record
CVE-2017-9864
Updated
2026-11-02
EUVDEUVD-2017-18774 No score

An issue was discovered in SMA Solar Technology products. An attacker can change the plant time even when not authenticated in any way. This changes the system time, possibly affecting lockout policies and random-number generators based on timestamps, and makes timestamps for data analysis unreliable. NOTE: the vendor reports that this is largely irrelevant because it only affects log-entry timestamps, and because the plant time would later be reset via NTP. (It has never been the case that a lockout policy or random-number generator was affected.) Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected

Record
EUVD-2017-18774
Updated
2026-11-03
GitHub AdvisoriesGHSA-w6cm-pp6c-p5vr 7.5

** DISPUTED ** An issue was discovered in SMA Solar Technology products. An attacker can change...

** DISPUTED ** An issue was discovered in SMA Solar Technology products. An attacker can change the plant time even when not authenticated in any way. This changes the system time, possibly affecting lockout policies and random-number generators based on timestamps, and makes timestamps for data analysis unreliable. NOTE: the vendor reports that this is largely irrelevant because it only affects log-entry timestamps, and because the plant time would later be reset via NTP. (It has never been the case that a lockout policy or random-number generator was affected.) Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected.

Record
GHSA-w6cm-pp6c-p5vr
CVSS 3.0
7.5 HighCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
Updated
2026-11-02

Affected products

Show 27 moreShow less

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2017-9864 is a high vulnerability (CVSS 7.5) in Sma Sunny Boy 1.5 Firmware, published August 5, 2017. Its validity is disputed. EPSS puts the chance of exploitation in the next 30 days at 1.51%, the 74th percentile.

References

MoveEnter Open