Every CVE Search/ Get API key

CVE-2017-12785

The novish command-line interface, included in the NoviWare software distribution through NW400.2...

9.8 CriticalPublic exploit

The novish command-line interface, included in the NoviWare software distribution through NW400.2.6 and deployed on NoviSwitch devices, is prone to a buffer overflow in the "show log cli" command. This could be used by a read-only user (monitor role) to gain privileged (root) code execution on the switch via command injection.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

16.0%Up 12.8 points since Apr 14, 2021
90%50%10%1%

What each source reports

NVD Score used 9.8

The novish command-line interface, included in the NoviWare software distribution through NW400.2.6 and deployed on NoviSwitch devices, is prone to a buffer overflow in the "show log cli" command. This could be used by a read-only user (monitor role) to gain privileged (root) code execution on the switch via command injection.

Record
CVE-2017-12785
CVSS 3.0
9.8 CriticalCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0
10.0 HighAV:N/AC:L/Au:N/C:C/I:C/A:C
Weakness
CWE-119
Updated
2026-11-02
CVE List No score

The novish command-line interface, included in the NoviWare software distribution through NW400.2.6 and deployed on NoviSwitch devices, is prone to a buffer overflow in the "show log cli" command. This could be used by a read-only user (monitor role) to gain privileged (root) code execution on the switch via command injection.

Record
CVE-2017-12785
Updated
2026-11-02
EUVDEUVD-2017-4324 No score

The novish command-line interface, included in the NoviWare software distribution through NW400.2.6 and deployed on NoviSwitch devices, is prone to a buffer overflow in the "show log cli" command. This could be used by a read-only user (monitor role) to gain privileged (root) code execution on the switch via command injection.

Record
EUVD-2017-4324
Updated
2026-11-03
GitHub AdvisoriesGHSA-vm86-9jrr-2v8f 9.8

The novish command-line interface, included in the NoviWare software distribution through NW400.2...

The novish command-line interface, included in the NoviWare software distribution through NW400.2.6 and deployed on NoviSwitch devices, is prone to a buffer overflow in the "show log cli" command. This could be used by a read-only user (monitor role) to gain privileged (root) code execution on the switch via command injection.

Record
GHSA-vm86-9jrr-2v8f
CVSS 3.0
9.8 CriticalCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-119
Updated
2026-11-02

Affected products

Public exploits

Links only. Every CVE stores no exploit code.

Public exploits
SourceLinkDate
Exploit-DBNoviFlow NoviWare < NW400.2.6 - Multiple Vulnerabilities2017-08-18

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, Exploit-DB, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2017-12785 is a critical vulnerability (CVSS 9.8) in Noviflow Noviware, published August 22, 2017. Public exploit code exists. EPSS puts the chance of exploitation in the next 30 days at 16.0%, the 96th percentile. No source names a fixed version.

References

MoveEnter Open