CVE-2017-12785
The novish command-line interface, included in the NoviWare software distribution through NW400.2...
The novish command-line interface, included in the NoviWare software distribution through NW400.2.6 and deployed on NoviSwitch devices, is prone to a buffer overflow in the "show log cli" command. This could be used by a read-only user (monitor role) to gain privileged (root) code execution on the switch via command injection.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
9.8
The novish command-line interface, included in the NoviWare software distribution through NW400.2.6 and deployed on NoviSwitch devices, is prone to a buffer overflow in the "show log cli" command. This could be used by a read-only user (monitor role) to gain privileged (root) code execution on the switch via command injection.
- Record
CVE-2017-12785- CVSS 3.0
- 9.8 Critical
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - CVSS 2.0
- 10.0 High
AV:N/AC:L/Au:N/C:C/I:C/A:C - Weakness
- CWE-119
- Updated
- 2026-11-02
CVE List No score
The novish command-line interface, included in the NoviWare software distribution through NW400.2.6 and deployed on NoviSwitch devices, is prone to a buffer overflow in the "show log cli" command. This could be used by a read-only user (monitor role) to gain privileged (root) code execution on the switch via command injection.
- Record
CVE-2017-12785- Updated
- 2026-11-02
EUVDEUVD-2017-4324 No score
The novish command-line interface, included in the NoviWare software distribution through NW400.2.6 and deployed on NoviSwitch devices, is prone to a buffer overflow in the "show log cli" command. This could be used by a read-only user (monitor role) to gain privileged (root) code execution on the switch via command injection.
- Record
EUVD-2017-4324- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-vm86-9jrr-2v8f
9.8
The novish command-line interface, included in the NoviWare software distribution through NW400.2...
The novish command-line interface, included in the NoviWare software distribution through NW400.2.6 and deployed on NoviSwitch devices, is prone to a buffer overflow in the "show log cli" command. This could be used by a read-only user (monitor role) to gain privileged (root) code execution on the switch via command injection.
- Record
GHSA-vm86-9jrr-2v8f- CVSS 3.0
- 9.8 Critical
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-119
- Updated
- 2026-11-02
Affected products
Public exploits
Links only. Every CVE stores no exploit code.
| Source | Link | Date |
|---|---|---|
| Exploit-DB | NoviFlow NoviWare < NW400.2.6 - Multiple Vulnerabilities | 2017-08-18 |
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, Exploit-DB, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2017-12785 is a critical vulnerability (CVSS 9.8) in Noviflow Noviware, published August 22, 2017. Public exploit code exists. EPSS puts the chance of exploitation in the next 30 days at 16.0%, the 96th percentile. No source names a fixed version.