CVE-2017-14375
EMC Unisphere for VMAX Virtual Appliance (vApp) versions prior to 8.4.0.15, EMC Solutions Enabler...
EMC Unisphere for VMAX Virtual Appliance (vApp) versions prior to 8.4.0.15, EMC Solutions Enabler Virtual Appliance versions prior to 8.4.0.15, EMC VASA Virtual Appliance versions prior to 8.4.0.512, and EMC VMAX Embedded Management (eManagement) versions prior to and including 1.4 (Enginuity Release 5977.1125.1125 and earlier) contain an authentication bypass vulnerability that may potentially be exploited by malicious users to compromise the affected system.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
9.8
EMC Unisphere for VMAX Virtual Appliance (vApp) versions prior to 8.4.0.15, EMC Solutions Enabler Virtual Appliance versions prior to 8.4.0.15, EMC VASA Virtual Appliance versions prior to 8.4.0.512, and EMC VMAX Embedded Management (eManagement) versions prior to and including 1.4 (Enginuity Release 5977.1125.1125 and earlier) contain an authentication bypass vulnerability that may potentially be exploited by malicious users to compromise the affected system.
- Record
CVE-2017-14375- CVSS 3.0
- 9.8 Critical
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - CVSS 2.0
- 10.0 High
AV:N/AC:L/Au:N/C:C/I:C/A:C - Weakness
- CWE-290
- Updated
- 2026-11-02
CVE List No score
EMC Unisphere for VMAX Virtual Appliance (vApp) versions prior to 8.4.0.15, EMC Solutions Enabler Virtual Appliance versions prior to 8.4.0.15, EMC VASA Virtual Appliance versions prior to 8.4.0.512, and EMC VMAX Embedded Management (eManagement) versions prior to and including 1.4 (Enginuity Release 5977.1125.1125 and earlier) contain an authentication bypass vulnerability that may potentially be exploited by malicious users to compromise the affected system.
- Record
CVE-2017-14375- Updated
- 2026-11-02
EUVDEUVD-2017-5878 No score
EMC Unisphere for VMAX Virtual Appliance (vApp) versions prior to 8.4.0.15, EMC Solutions Enabler Virtual Appliance versions prior to 8.4.0.15, EMC VASA Virtual Appliance versions prior to 8.4.0.512, and EMC VMAX Embedded Management (eManagement) versions prior to and including 1.4 (Enginuity Release 5977.1125.1125 and earlier) contain an authentication bypass vulnerability that may potentially be exploited by malicious users to compromise the affected system.
- Record
EUVD-2017-5878- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-3mf6-cpxv-733m
9.8
EMC Unisphere for VMAX Virtual Appliance (vApp) versions prior to 8.4.0.15, EMC Solutions Enabler...
EMC Unisphere for VMAX Virtual Appliance (vApp) versions prior to 8.4.0.15, EMC Solutions Enabler Virtual Appliance versions prior to 8.4.0.15, EMC VASA Virtual Appliance versions prior to 8.4.0.512, and EMC VMAX Embedded Management (eManagement) versions prior to and including 1.4 (Enginuity Release 5977.1125.1125 and earlier) contain an authentication bypass vulnerability that may potentially be exploited by malicious users to compromise the affected system.
- Record
GHSA-3mf6-cpxv-733m- CVSS 3.0
- 9.8 Critical
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-290
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2017-14375 is a critical vulnerability (CVSS 9.8) in Dell Emc Unisphere, published November 1, 2017. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 4.77%, the 91st percentile. No source names a fixed version.