CVE-2017-17877
An issue was discovered in Valve Steam Link build 643. When the SSH daemon is enabled for local...
An issue was discovered in Valve Steam Link build 643. When the SSH daemon is enabled for local development, the device is publicly available via IPv6 TCP port 22 over the internet (with stateless address autoconfiguration) by default, which makes it easier for remote attackers to obtain access by guessing 24 bits of the MAC address and attempting a root login. This can be exploited in conjunction with CVE-2017-17878.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
9.8
An issue was discovered in Valve Steam Link build 643. When the SSH daemon is enabled for local development, the device is publicly available via IPv6 TCP port 22 over the internet (with stateless address autoconfiguration) by default, which makes it easier for remote attackers to obtain access by guessing 24 bits of the MAC address and attempting a root login. This can be exploited in conjunction with CVE-2017-17878.
- Record
CVE-2017-17877- CVSS 3.0
- 9.8 Critical
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - CVSS 2.0
- 10.0 High
AV:N/AC:L/Au:N/C:C/I:C/A:C - Updated
- 2026-11-02
CVE List No score
An issue was discovered in Valve Steam Link build 643. When the SSH daemon is enabled for local development, the device is publicly available via IPv6 TCP port 22 over the internet (with stateless address autoconfiguration) by default, which makes it easier for remote attackers to obtain access by guessing 24 bits of the MAC address and attempting a root login. This can be exploited in conjunction with CVE-2017-17878.
- Record
CVE-2017-17877- Updated
- 2026-11-02
EUVDEUVD-2017-9024 No score
An issue was discovered in Valve Steam Link build 643. When the SSH daemon is enabled for local development, the device is publicly available via IPv6 TCP port 22 over the internet (with stateless address autoconfiguration) by default, which makes it easier for remote attackers to obtain access by guessing 24 bits of the MAC address and attempting a root login. This can be exploited in conjunction with CVE-2017-17878.
- Record
EUVD-2017-9024- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-wjcr-9rvj-672v
9.8
An issue was discovered in Valve Steam Link build 643. When the SSH daemon is enabled for local...
An issue was discovered in Valve Steam Link build 643. When the SSH daemon is enabled for local development, the device is publicly available via IPv6 TCP port 22 over the internet (with stateless address autoconfiguration) by default, which makes it easier for remote attackers to obtain access by guessing 24 bits of the MAC address and attempting a root login. This can be exploited in conjunction with CVE-2017-17878.
- Record
GHSA-wjcr-9rvj-672v- CVSS 3.0
- 9.8 Critical
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2017-17877 is a critical vulnerability (CVSS 9.8) in Valvesoftware Steam Link Firmware, published December 24, 2017. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 4.10%, the 90th percentile. No source names a fixed version.