CVE-2018-5453
An Improper Handling of Length Parameter Inconsistency issue was discovered in Moxa OnCell G3100...
An Improper Handling of Length Parameter Inconsistency issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker may be able to edit the element of an HTTP request, causing the device to become unavailable.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- None
- Integrity
- None
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
7.5
An Improper Handling of Length Parameter Inconsistency issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker may be able to edit the element of an HTTP request, causing the device to become unavailable.
- Record
CVE-2018-5453- CVSS 3.0
- 7.5 High
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H - CVSS 2.0
- 7.8 High
AV:N/AC:L/Au:N/C:N/I:N/A:C - Weakness
- CWE-130, CWE-119
- Updated
- 2026-11-02
CVE List No score
An Improper Handling of Length Parameter Inconsistency issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker may be able to edit the element of an HTTP request, causing the device to become unavailable.
- Record
CVE-2018-5453- Weakness
- CWE-130
- Updated
- 2026-11-02
EUVDEUVD-2018-17223 No score
An Improper Handling of Length Parameter Inconsistency issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker may be able to edit the element of an HTTP request, causing the device to become unavailable.
- Record
EUVD-2018-17223- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-f5fj-f6xf-9jxc
7.5
An Improper Handling of Length Parameter Inconsistency issue was discovered in Moxa OnCell G3100...
An Improper Handling of Length Parameter Inconsistency issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker may be able to edit the element of an HTTP request, causing the device to become unavailable.
- Record
GHSA-f5fj-f6xf-9jxc- CVSS 3.0
- 7.5 High
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H - Weakness
- CWE-119
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short