CVE-2018-8827
The admin web interface on Technicolor MediaAccess TG789vac v2 HP devices with firmware v16.3...
The admin web interface on Technicolor MediaAccess TG789vac v2 HP devices with firmware v16.3.7190-2761005-20161004084353 displays unsanitised user input, which allows an unauthenticated malicious user to embed JavaScript into the Log viewer interface via a crafted HTTP Referer header, aka XSS.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- Required
What an attacker can affect
- Confidentiality
- Low
- Integrity
- Low
- Availability
- None
Exploit likelihood
What each source reports
NVD Score used
6.1
The admin web interface on Technicolor MediaAccess TG789vac v2 HP devices with firmware v16.3.7190-2761005-20161004084353 displays unsanitised user input, which allows an unauthenticated malicious user to embed JavaScript into the Log viewer interface via a crafted HTTP Referer header, aka XSS.
- Record
CVE-2018-8827- CVSS 3.0
- 6.1 Medium
CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N - CVSS 2.0
- 4.3 Medium
AV:N/AC:M/Au:N/C:N/I:P/A:N - Weakness
- CWE-79
- Updated
- 2026-11-02
CVE List No score
The admin web interface on Technicolor MediaAccess TG789vac v2 HP devices with firmware v16.3.7190-2761005-20161004084353 displays unsanitised user input, which allows an unauthenticated malicious user to embed JavaScript into the Log viewer interface via a crafted HTTP Referer header, aka XSS.
- Record
CVE-2018-8827- Updated
- 2026-11-02
EUVDEUVD-2018-20435 No score
The admin web interface on Technicolor MediaAccess TG789vac v2 HP devices with firmware v16.3.7190-2761005-20161004084353 displays unsanitised user input, which allows an unauthenticated malicious user to embed JavaScript into the Log viewer interface via a crafted HTTP Referer header, aka XSS.
- Record
EUVD-2018-20435- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-fhq6-q29j-x78v
6.1
The admin web interface on Technicolor MediaAccess TG789vac v2 HP devices with firmware v16.3...
The admin web interface on Technicolor MediaAccess TG789vac v2 HP devices with firmware v16.3.7190-2761005-20161004084353 displays unsanitised user input, which allows an unauthenticated malicious user to embed JavaScript into the Log viewer interface via a crafted HTTP Referer header, aka XSS.
- Record
GHSA-fhq6-q29j-x78v- CVSS 3.0
- 6.1 Medium
CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N - Weakness
- CWE-79
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2018-8827 is a medium vulnerability (CVSS 6.1) in Technicolor Tg789vac Firmware, published January 3, 2019. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.22%, the 68th percentile. No source names a fixed version.