Every CVE Search/ Get API key

CVE-2018-8842

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software transmits...

8.8 High

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. The Philips e-Alert communication channel is not encrypted which could therefore lead to disclosure of personal contact information and application login credentials from within the same subnet.

Attack profile

How easy it is to exploit

Attack vector
Adjacent network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

0.57%Down 0.3 points since Apr 14, 2021
90%50%10%1%

What each source reports

NVD Score used 8.8

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. The Philips e-Alert communication channel is not encrypted which could therefore lead to disclosure of personal contact information and application login credentials from within the same subnet.

Record
CVE-2018-8842
CVSS 3.0
8.8 HighCVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0
3.3 LowAV:A/AC:L/Au:N/C:P/I:N/A:N
Weakness
CWE-319
Updated
2026-11-02
CVE List No score

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. The Philips e-Alert communication channel is not encrypted which could therefore lead to disclosure of personal contact information and application login credentials from within the same subnet.

Record
CVE-2018-8842
Weakness
CWE-319
Updated
2026-11-02
EUVDEUVD-2018-20450 No score

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. The Philips e-Alert communication channel is not encrypted which could therefore lead to disclosure of personal contact information and application login credentials from within the same subnet.

Record
EUVD-2018-20450
Updated
2026-11-03
GitHub AdvisoriesGHSA-28h5-j8xc-vfgg 8.8

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software transmits...

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. The Philips e-Alert communication channel is not encrypted which could therefore lead to disclosure of personal contact information and application login credentials from within the same subnet.

Record
GHSA-28h5-j8xc-vfgg
CVSS 3.0
8.8 HighCVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-319
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2018-8842 is a high vulnerability (CVSS 8.8) in Philips E-alert Unit (non-medical Device), published September 26, 2018. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.57%, the 47th percentile. No source names a fixed version.

References

MoveEnter Open