Every CVE Search/ Get API key

CVE-2018-9276

An issue was discovered in PRTG Network Monitor before 18.2.39. An attacker who has access to the...

7.2 HighIn KEVPublic exploit

An issue was discovered in PRTG Network Monitor before 18.2.39. An attacker who has access to the PRTG System Administrator web console with administrative privileges can exploit an OS command injection vulnerability (both on the server and on devices) by sending malformed parameters in sensor or notification management scenarios.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
High
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

87.0%Up 60.0 points since Apr 14, 2021
90%50%10%1%

What each source reports

NVD Score used 7.2

An issue was discovered in PRTG Network Monitor before 18.2.39. An attacker who has access to the PRTG System Administrator web console with administrative privileges can exploit an OS command injection vulnerability (both on the server and on devices) by sending malformed parameters in sensor or notification management scenarios.

Record
CVE-2018-9276
CVSS 3.1
7.2 HighCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0
9.0 HighAV:N/AC:L/Au:S/C:C/I:C/A:C
Weakness
CWE-78
Updated
2026-11-02
CVE List 7.2

An issue was discovered in PRTG Network Monitor before 18.2.39. An attacker who has access to the PRTG System Administrator web console with administrative privileges can exploit an OS command injection vulnerability (both on the server and on devices) by sending malformed parameters in sensor or notification management scenarios.

Record
CVE-2018-9276
CVSS 3.1
7.2 HighCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-78
Updated
2026-11-02
EUVDEUVD-2018-20870 7.2

An issue was discovered in PRTG Network Monitor before 18.2.39. An attacker who has access to the PRTG System Administrator web console with administrative privileges can exploit an OS command injection vulnerability (both on the server and on devices) by sending malformed parameters in sensor or notification management scenarios.

Record
EUVD-2018-20870
CVSS 3.1
7.2 HighCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Updated
2026-11-02
GitHub AdvisoriesGHSA-cjqq-8xv6-575p 7.2

An issue was discovered in PRTG Network Monitor before 18.2.39. An attacker who has access to the...

An issue was discovered in PRTG Network Monitor before 18.2.39. An attacker who has access to the PRTG System Administrator web console with administrative privileges can exploit an OS command injection vulnerability (both on the server and on devices) by sending malformed parameters in sensor or notification management scenarios.

Record
GHSA-cjqq-8xv6-575p
CVSS 3.1
7.2 HighCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-78
Updated
2026-11-02
CISA KEV No score

Paessler PRTG Network Monitor OS Command Injection Vulnerability

Paessler PRTG Network Monitor contains an OS command injection vulnerability that allows an attacker with administrative privileges to execute commands via the PRTG System Administrator web console.

Record
CVE-2018-9276
Weakness
CWE-78
Updated
2026-11-02

Affected products

Public exploits

Links only. Every CVE stores no exploit code.

History

History
RecordedChangedSources
exploitation, exploits
first indexedCVE List, EUVD, Exploit-DB, GitHub Advisories, CISA KEV, Metasploit, NVD, PoC in GitHub

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2018-9276 is a high vulnerability (CVSS 7.2) in Paessler Prtg Network Monitor, published July 2, 2018. CISA lists it as known to be exploited, since February 4, 2025. EUVD reports exploitation since February 4, 2025. Public exploit code exists. EPSS puts the chance of exploitation in the next 30 days at 87.0%, the 99th percentile. No source names a fixed version.

References

MoveEnter Open