CVE-2018-14495
Vivotek FD8136 devices allow Remote Command Injection, aka "another command injection...
Vivotek FD8136 devices allow Remote Command Injection, aka "another command injection vulnerability in our target device," a different issue than CVE-2018-14494. NOTE: The vendor has disputed this as a vulnerability and states that the issue does not cause a web server crash or have any other affect on it's performance
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
9.8
Vivotek FD8136 devices allow Remote Command Injection, aka "another command injection vulnerability in our target device," a different issue than CVE-2018-14494. NOTE: The vendor has disputed this as a vulnerability and states that the issue does not cause a web server crash or have any other affect on it's performance
- Record
CVE-2018-14495- CVSS 3.0
- 9.8 Critical
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - CVSS 2.0
- 10.0 High
AV:N/AC:L/Au:N/C:C/I:C/A:C - Weakness
- CWE-78
- Updated
- 2026-11-02
CVE List No score
Vivotek FD8136 devices allow Remote Command Injection, aka "another command injection vulnerability in our target device," a different issue than CVE-2018-14494. NOTE: The vendor has disputed this as a vulnerability and states that the issue does not cause a web server crash or have any other affect on it's performance
- Record
CVE-2018-14495- Updated
- 2026-11-02
EUVDEUVD-2018-6411 No score
Vivotek FD8136 devices allow Remote Command Injection, aka "another command injection vulnerability in our target device," a different issue than CVE-2018-14494. NOTE: The vendor has disputed this as a vulnerability and states that the issue does not cause a web server crash or have any other affect on it's performance
- Record
EUVD-2018-6411- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-8q8q-vh64-gvf8
9.8
Vivotek FD8136 devices allow Remote Command Injection, aka "another command injection...
Vivotek FD8136 devices allow Remote Command Injection, aka "another command injection vulnerability in our target device," a different issue than CVE-2018-14494.
- Record
GHSA-8q8q-vh64-gvf8- CVSS 3.0
- 9.8 Critical
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-78
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2018-14495 is a critical vulnerability (CVSS 9.8) in Vivotek Fd8136 Firmware, published July 10, 2019. Its validity is disputed. EPSS puts the chance of exploitation in the next 30 days at 4.41%, the 91st percentile.