CVE-2018-15480
An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi...
An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. The cloud API had a hidden parameter, which allowed an authenticated user to reconfigure the server URL for a device registered to their account. In combination with an insecure device registration vulnerability, this allowed an attacker to reconfigure a maliciously registered device to their own rogue replica of the myStrom API and issue commands to the device, including firmware update commands.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- Low
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
8.8
An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. The cloud API had a hidden parameter, which allowed an authenticated user to reconfigure the server URL for a device registered to their account. In combination with an insecure device registration vulnerability, this allowed an attacker to reconfigure a maliciously registered device to their own rogue replica of the myStrom API and issue commands to the device, including firmware update commands.
- Record
CVE-2018-15480- CVSS 3.0
- 8.8 High
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - CVSS 2.0
- 6.5 Medium
AV:N/AC:L/Au:S/C:P/I:P/A:P - Updated
- 2026-11-02
CVE List No score
An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. The cloud API had a hidden parameter, which allowed an authenticated user to reconfigure the server URL for a device registered to their account. In combination with an insecure device registration vulnerability, this allowed an attacker to reconfigure a maliciously registered device to their own rogue replica of the myStrom API and issue commands to the device, including firmware update commands.
- Record
CVE-2018-15480- Updated
- 2026-11-02
EUVDEUVD-2018-7358 No score
An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. The cloud API had a hidden parameter, which allowed an authenticated user to reconfigure the server URL for a device registered to their account. In combination with an insecure device registration vulnerability, this allowed an attacker to reconfigure a maliciously registered device to their own rogue replica of the myStrom API and issue commands to the device, including firmware update commands.
- Record
EUVD-2018-7358- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-c72h-v39q-xwhh
8.8
An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi...
An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. The cloud API had a hidden parameter, which allowed an authenticated user to reconfigure the server URL for a device registered to their account. In combination with an insecure device registration vulnerability, this allowed an attacker to reconfigure a maliciously registered device to their own rogue replica of the myStrom API and issue commands to the device, including firmware update commands.
- Record
GHSA-c72h-v39q-xwhh- CVSS 3.0
- 8.8 High
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2018-15480 is a high vulnerability (CVSS 8.8) in Mystrom Wifi Bulb Firmware, published August 30, 2018. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.02%, the 63rd percentile. No source names a fixed version.