Every CVE Search/ Get API key

CVE-2019-5644

C4G BLIS Improper Access Control

10.0 Critical

Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may alter several facets of a user account, including promoting any user to an administrator.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

1.32%Up 0.9 points since Apr 14, 2021
90%50%10%1%

What each source reports

CVE List Score used 10.0

C4G BLIS Improper Access Control

Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may alter several facets of a user account, including promoting any user to an administrator.

Record
CVE-2019-5644
CVSS 3.1
10.0 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Weakness
CWE-284
Updated
2026-11-02
EUVDEUVD-2019-15219 10.0

Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may alter several facets of a user account, including promoting any user to an administrator.

Record
EUVD-2019-15219
CVSS 3.1
10.0 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Updated
2026-11-03
GitHub AdvisoriesGHSA-pfxc-95p3-jhv6 9.8

Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and...

Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may alter several facets of a user account, including promoting any user to an administrator.

Record
GHSA-pfxc-95p3-jhv6
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-284, CWE-306
Updated
2026-11-02
NVD 10.0

Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may alter several facets of a user account, including promoting any user to an administrator.

Record
CVE-2019-5644
CVSS 3.1
10.0 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0
7.5 HighAV:N/AC:L/Au:N/C:P/I:P/A:P
Weakness
CWE-284, CWE-306
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliases, products, publishedEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2019-5644 is a critical vulnerability (CVSS 10.0) in C4g Basic Laboratory Information System, published November 6, 2019. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.32%, the 70th percentile. No source names a fixed version.

References

MoveEnter Open