CVE-2019-6528
PSI GridConnect GmbH Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy...
PSI GridConnect GmbH Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy versions Telecontrol Gateway 3G Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway XS-MU Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway VM Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Smart Telecontrol Unit TCG Versions 5.0.27, 5.1.19, 6.0.16 and prior, and IEC104 Security Proxy Version 2.2.10 and prior The web application browser interprets input as active HTML, JavaScript, or VBScript, which could allow an attacker to execute arbitrary code.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- Low
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
8.8
PSI GridConnect GmbH Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy versions Telecontrol Gateway 3G Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway XS-MU Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway VM Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Smart Telecontrol Unit TCG Versions 5.0.27, 5.1.19, 6.0.16 and prior, and IEC104 Security Proxy Version 2.2.10 and prior The web application browser interprets input as active HTML, JavaScript, or VBScript, which could allow an attacker to execute arbitrary code.
- Record
CVE-2019-6528- CVSS 3.1
- 8.8 High
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - CVSS 2.0
- 6.5 Medium
AV:N/AC:L/Au:S/C:P/I:P/A:P - Weakness
- CWE-79
- Updated
- 2026-11-02
CVE List No score
PSI GridConnect GmbH Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy versions Telecontrol Gateway 3G Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway XS-MU Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway VM Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Smart Telecontrol Unit TCG Versions 5.0.27, 5.1.19, 6.0.16 and prior, and IEC104 Security Proxy Version 2.2.10 and prior The web application browser interprets input as active HTML, JavaScript, or VBScript, which could allow an attacker to execute arbitrary code.
- Record
CVE-2019-6528- Weakness
- CWE-79
- Updated
- 2026-11-02
EUVDEUVD-2019-16087 No score
PSI GridConnect GmbH Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy versions Telecontrol Gateway 3G Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway XS-MU Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway VM Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Smart Telecontrol Unit TCG Versions 5.0.27, 5.1.19, 6.0.16 and prior, and IEC104 Security Proxy Version 2.2.10 and prior The web application browser interprets input as active HTML, JavaScript, or VBScript, which could allow an attacker to execute arbitrary code.
- Record
EUVD-2019-16087- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-45cc-q6w5-96r8
8.8
PSI GridConnect GmbH Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy...
PSI GridConnect GmbH Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy versions Telecontrol Gateway 3G Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway XS-MU Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway VM Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Smart Telecontrol Unit TCG Versions 5.0.27, 5.1.19, 6.0.16 and prior, and IEC104 Security Proxy Version 2.2.10 and prior The web application browser interprets input as active HTML, JavaScript, or VBScript, which could allow an attacker to execute arbitrary code.
- Record
GHSA-45cc-q6w5-96r8- CVSS 3.1
- 8.8 High
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-79
- Updated
- 2026-11-02
Affected products
- ics-cert psi gridconnect gmbh (formerly known as psi nentec gmbh) telecontrol gateway and smart telecontrol unit family, iec104 security proxy.
- psigridconnect iec104 security proxy firmware
- psigridconnect smart telecontrol unit tcg firmware
- psigridconnect telecontrol gateway 3g firmware
- psigridconnect telecontrol gateway vm firmware
- psigridconnect telecontrol gateway xs-mu firmware
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2019-6528 is a high vulnerability (CVSS 8.8) in Ics-cert Psi Gridconnect Gmbh (formerly Known As Psi Nentec Gmbh) Telecontrol Gateway And Smart Telecontrol Unit Family, Iec104 Security Proxy., published March 5, 2019. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 2.58%, the 85th percentile. No source names a fixed version.