CVE-2019-10658
Grandstream GWN7610 before 1.0.8.18 devices allow remote authenticated users to execute arbitrary...
Grandstream GWN7610 before 1.0.8.18 devices allow remote authenticated users to execute arbitrary code via shell metacharacters in the filename in a /ubus/controller.icc.update_nds_webroot_from_tmp update_nds_webroot_from_tmp API call.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- Low
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
8.8
Grandstream GWN7610 before 1.0.8.18 devices allow remote authenticated users to execute arbitrary code via shell metacharacters in the filename in a /ubus/controller.icc.update_nds_webroot_from_tmp update_nds_webroot_from_tmp API call.
- Record
CVE-2019-10658- CVSS 3.1
- 8.8 High
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - CVSS 2.0
- 6.5 Medium
AV:N/AC:L/Au:S/C:P/I:P/A:P - Weakness
- CWE-78
- Updated
- 2026-11-02
CVE List No score
Grandstream GWN7610 before 1.0.8.18 devices allow remote authenticated users to execute arbitrary code via shell metacharacters in the filename in a /ubus/controller.icc.update_nds_webroot_from_tmp update_nds_webroot_from_tmp API call.
- Record
CVE-2019-10658- Updated
- 2026-11-02
EUVDEUVD-2019-2458 No score
Grandstream GWN7610 before 1.0.8.18 devices allow remote authenticated users to execute arbitrary code via shell metacharacters in the filename in a /ubus/controller.icc.update_nds_webroot_from_tmp update_nds_webroot_from_tmp API call.
- Record
EUVD-2019-2458- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-592x-9cgq-g8gh
8.8
Grandstream GWN7610 before 1.0.8.18 devices allow remote authenticated users to execute arbitrary...
Grandstream GWN7610 before 1.0.8.18 devices allow remote authenticated users to execute arbitrary code via shell metacharacters in the filename in a /ubus/controller.icc.update_nds_webroot_from_tmp update_nds_webroot_from_tmp API call.
- Record
GHSA-592x-9cgq-g8gh- CVSS 3.0
- 8.8 High
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-78
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2019-10658 is a high vulnerability (CVSS 8.8) in Grandstream Gwn7610 Firmware, published March 30, 2019. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 2.64%, the 85th percentile. No source names a fixed version.