Every CVE Search/ Get API key

CVE-2019-15948

Texas Instruments CC256x and WL18xx dual-mode Bluetooth controller devices, when LE scan mode is...

8.8 High

Texas Instruments CC256x and WL18xx dual-mode Bluetooth controller devices, when LE scan mode is used, allow remote attackers to trigger a buffer overflow via a malformed Bluetooth Low Energy advertising packet, to cause a denial of service or potentially execute arbitrary code. This affects CC256xC-BT-SP 1.2, CC256xB-BT-SP 1.8, and WL18xx-BT-SP 4.4.

Attack profile

How easy it is to exploit

Attack vector
Adjacent network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

2.53%Down 0.8 points since Apr 14, 2021
90%50%10%1%

What each source reports

NVD Score used 8.8

Texas Instruments CC256x and WL18xx dual-mode Bluetooth controller devices, when LE scan mode is used, allow remote attackers to trigger a buffer overflow via a malformed Bluetooth Low Energy advertising packet, to cause a denial of service or potentially execute arbitrary code. This affects CC256xC-BT-SP 1.2, CC256xB-BT-SP 1.8, and WL18xx-BT-SP 4.4.

Record
CVE-2019-15948
CVSS 3.1
8.8 HighCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0
5.8 MediumAV:A/AC:L/Au:N/C:P/I:P/A:P
Weakness
CWE-120
Updated
2026-11-02
CVE List No score

Texas Instruments CC256x and WL18xx dual-mode Bluetooth controller devices, when LE scan mode is used, allow remote attackers to trigger a buffer overflow via a malformed Bluetooth Low Energy advertising packet, to cause a denial of service or potentially execute arbitrary code. This affects CC256xC-BT-SP 1.2, CC256xB-BT-SP 1.8, and WL18xx-BT-SP 4.4.

Record
CVE-2019-15948
Updated
2026-11-02
EUVDEUVD-2019-6849 No score

Texas Instruments CC256x and WL18xx dual-mode Bluetooth controller devices, when LE scan mode is used, allow remote attackers to trigger a buffer overflow via a malformed Bluetooth Low Energy advertising packet, to cause a denial of service or potentially execute arbitrary code. This affects CC256xC-BT-SP 1.2, CC256xB-BT-SP 1.8, and WL18xx-BT-SP 4.4.

Record
EUVD-2019-6849
Updated
2026-11-03
GitHub AdvisoriesGHSA-2jrq-wx46-frqw 8.8

Texas Instruments CC256x and WL18xx dual-mode Bluetooth controller devices, when LE scan mode is...

Texas Instruments CC256x and WL18xx dual-mode Bluetooth controller devices, when LE scan mode is used, allow remote attackers to trigger a buffer overflow via a malformed Bluetooth Low Energy advertising packet, to cause a denial of service or potentially execute arbitrary code. This affects CC256xC-BT-SP 1.2, CC256xB-BT-SP 1.8, and WL18xx-BT-SP 4.4.

Record
GHSA-2jrq-wx46-frqw
CVSS 3.1
8.8 HighCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-120
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2019-15948 is a high vulnerability (CVSS 8.8) in Ti Cc256xb-bt-sp Firmware, published November 13, 2019. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 2.53%, the 84th percentile. No source names a fixed version.

References

MoveEnter Open