CVE-2019-17101
Command execution due to unsanitized input in Netatmo Smart Indoor Security Camera
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in firmware versions prior to x.xx of Netatmo Smart Indoor Camera allows an attacker to execute commands on the device. This issue affects: Netatmo Smart Indoor Camera version and prior versions.
Attack profile
How easy it is to exploit
- Attack vector
- Local
- Complexity
- Low
- Privileges needed
- High
- User interaction
- None
What an attacker can affect
- Confidentiality
- Low
- Integrity
- Low
- Availability
- Low
Exploit likelihood
What each source reports
CVE List Score used
5.7
Command execution due to unsanitized input in Netatmo Smart Indoor Security Camera
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in firmware versions prior to x.xx of Netatmo Smart Indoor Camera allows an attacker to execute commands on the device. This issue affects: Netatmo Smart Indoor Camera version and prior versions.
- Record
CVE-2019-17101- CVSS 3.1
- 5.7 Medium
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:L - Weakness
- CWE-77
- Updated
- 2026-11-02
EUVDEUVD-2019-7567
5.7
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in firmware versions prior to x.xx of Netatmo Smart Indoor Camera allows an attacker to execute commands on the device. This issue affects: Netatmo Smart Indoor Camera version and prior versions.
- Record
EUVD-2019-7567- CVSS 3.1
- 5.7 Medium
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:L - Updated
- 2026-11-03
GitHub AdvisoriesGHSA-cm5r-wgmx-pg96 No score
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability...
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in firmware versions prior to x.xx of Netatmo Smart Indoor Camera allows an attacker to execute commands on the device. This issue affects: Netatmo Smart Indoor Camera version and prior versions.
- Record
GHSA-cm5r-wgmx-pg96- Weakness
- CWE-77
- Updated
- 2026-11-02
NVD
5.7
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in firmware versions prior to x.xx of Netatmo Smart Indoor Camera allows an attacker to execute commands on the device. This issue affects: Netatmo Smart Indoor Camera version and prior versions.
- Record
CVE-2019-17101- CVSS 3.1
- 5.7 Medium
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:L - CVSS 3.1
- 6.7 Medium
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H - CVSS 2.0
- 4.6 Medium
AV:L/AC:L/Au:N/C:P/I:P/A:P - Weakness
- CWE-77
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases, published | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2019-17101 is a medium vulnerability (CVSS 5.7) in Netatmo Smart Indoor Camera, published April 23, 2020. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.85%, the 58th percentile. No source names a fixed version.