Every CVE Search/ Get API key

CVE-2021-30065

On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21,...

7.5 High

On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, crafted ModBus packets can bypass the ModBus enforcer. NOTE: this issue exists because of an incomplete fix of CVE-2017-11401.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
None
Integrity
High
Availability
None

Exploit likelihood

0.88%Unchanged since Apr 4, 2022
90%50%10%1%

What each source reports

CVE List Score used 7.5

On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, crafted ModBus packets can bypass the ModBus enforcer. NOTE: this issue exists because of an incomplete fix of CVE-2017-11401.

Record
CVE-2021-30065
CVSS 3.1
7.5 HighCVSS:3.1/AC:L/AV:N/A:N/C:N/I:H/PR:N/S:U/UI:N
Updated
2026-11-02
EUVDEUVD-2021-17009 7.5

On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, crafted ModBus packets can bypass the ModBus enforcer. NOTE: this issue exists because of an incomplete fix of CVE-2017-11401.

Record
EUVD-2021-17009
CVSS 3.1
7.5 HighCVSS:3.1/AC:L/AV:N/A:N/C:N/I:H/PR:N/S:U/UI:N
Updated
2026-11-03
GitHub AdvisoriesGHSA-264c-27mg-g32w 7.5

On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21,...

On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, crafted ModBus packets can bypass the ModBus enforcer. NOTE: this issue exists because of an incomplete fix of CVE-2017-11401.

Record
GHSA-264c-27mg-g32w
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
Updated
2026-11-02
NVD 7.5

On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, crafted ModBus packets can bypass the ModBus enforcer. NOTE: this issue exists because of an incomplete fix of CVE-2017-11401.

Record
CVE-2021-30065
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
CVSS 2.0
5.0 MediumAV:N/AC:L/Au:N/C:N/I:P/A:N
Updated
2026-11-02

Affected products

Show 1 moreShow less

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2021-30065 is a high vulnerability (CVSS 7.5) in Belden Eagle 20 Tofino 943 987-501-tx\/tx Firmware, published April 3, 2022. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.88%, the 59th percentile. No source names a fixed version.

References

MoveEnter Open