CVE-2021-33004
The affected product is vulnerable to memory corruption condition due to lack of proper...
The affected product is vulnerable to memory corruption condition due to lack of proper validation of user supplied files, which may allow an attacker to execute arbitrary code. User interaction is required on the WebAccess HMI Designer (versions 2.1.9.95 and prior).
Attack profile
How easy it is to exploit
- Attack vector
- Local
- Complexity
- Low
- Privileges needed
- None
- User interaction
- Required
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
7.8
The affected product is vulnerable to memory corruption condition due to lack of proper validation of user supplied files, which may allow an attacker to execute arbitrary code. User interaction is required on the WebAccess HMI Designer (versions 2.1.9.95 and prior).
- Record
CVE-2021-33004- CVSS 3.1
- 7.8 High
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H - CVSS 2.0
- 6.8 Medium
AV:N/AC:M/Au:N/C:P/I:P/A:P - Weakness
- CWE-119, CWE-787
- Updated
- 2026-11-02
CVE List No score
The affected product is vulnerable to memory corruption condition due to lack of proper validation of user supplied files, which may allow an attacker to execute arbitrary code. User interaction is required on the WebAccess HMI Designer (versions 2.1.9.95 and prior).
- Record
CVE-2021-33004- Weakness
- CWE-119
- Updated
- 2026-11-02
EUVDEUVD-2021-19725 No score
The affected product is vulnerable to memory corruption condition due to lack of proper validation of user supplied files, which may allow an attacker to execute arbitrary code. User interaction is required on the WebAccess HMI Designer (versions 2.1.9.95 and prior).
- Record
EUVD-2021-19725- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-q569-xrrr-6gvr
7.8
The affected product is vulnerable to memory corruption condition due to lack of proper...
The affected product is vulnerable to memory corruption condition due to lack of proper validation of user supplied files, which may allow an attacker to execute arbitrary code. User interaction is required on the WebAccess HMI Designer (versions 2.1.9.95 and prior).
- Record
GHSA-q569-xrrr-6gvr- CVSS 3.1
- 7.8 High
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H - Weakness
- CWE-119, CWE-787
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases, products | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short