Every CVE Search/ Get API key

CVE-2022-37459

Ampere Altra devices before 1.08g and Ampere Altra Max devices before 2.05a allow attackers to...

7.8 High

Ampere Altra devices before 1.08g and Ampere Altra Max devices before 2.05a allow attackers to control the predictions for return addresses and potentially hijack code flow to execute arbitrary code via a side-channel attack, aka a "Retbleed" issue.

Attack profile

How easy it is to exploit

Attack vector
Local
Complexity
Low
Privileges needed
Low
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

0.22%Down 2.3 points since Aug 18, 2022
90%50%10%1%

What each source reports

NVD Score used 7.8

Ampere Altra devices before 1.08g and Ampere Altra Max devices before 2.05a allow attackers to control the predictions for return addresses and potentially hijack code flow to execute arbitrary code via a side-channel attack, aka a "Retbleed" issue.

Record
CVE-2022-37459
CVSS 3.1
7.8 HighCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-203
Updated
2026-11-02
CVE List No score

Ampere Altra devices before 1.08g and Ampere Altra Max devices before 2.05a allow attackers to control the predictions for return addresses and potentially hijack code flow to execute arbitrary code via a side-channel attack, aka a "Retbleed" issue.

Record
CVE-2022-37459
Updated
2026-11-02
EUVDEUVD-2022-40084 No score

Ampere Altra devices before 1.08g and Ampere Altra Max devices before 2.05a allow attackers to control the predictions for return addresses and potentially hijack code flow to execute arbitrary code via a side-channel attack, aka a "Retbleed" issue.

Record
EUVD-2022-40084
Updated
2026-11-03
GitHub AdvisoriesGHSA-gp65-59gv-vqpf 7.8

Ampere Altra devices before 1.08g and Ampere Altra Max devices before 2.05a allow attackers to...

Ampere Altra devices before 1.08g and Ampere Altra Max devices before 2.05a allow attackers to control the predictions for return addresses and potentially hijack code flow to execute arbitrary code via a side-channel attack, aka a "Retbleed" issue.

Record
GHSA-gp65-59gv-vqpf
CVSS 3.1
7.8 HighCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-203
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2022-37459 is a high vulnerability (CVSS 7.8) in Amperecomputing Ampere Altra Firmware, published August 17, 2022. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.22%, the 13th percentile. No source names a fixed version.