CVE-2023-4212
Trane Thermostats Injection
A command injection vulnerability exists in Trane XL824, XL850, XL1050, and Pivot thermostats allowing an attacker to execute arbitrary commands as root using a specially crafted filename. The vulnerability requires physical access to the device via a USB stick.
Attack profile
How easy it is to exploit
- Attack vector
- Physical
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
CVE List Score used
6.8
Trane Thermostats Injection
A command injection vulnerability exists in Trane XL824, XL850, XL1050, and Pivot thermostats allowing an attacker to execute arbitrary commands as root using a specially crafted filename. The vulnerability requires physical access to the device via a USB stick.
- Record
CVE-2023-4212- CVSS 3.1
- 6.8 Medium
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-74
- Updated
- 2026-11-02
EUVDEUVD-2023-54086
6.8
A command injection vulnerability exists in Trane XL824, XL850, XL1050, and Pivot thermostats allowing an attacker to execute arbitrary commands as root using a specially crafted filename. The vulnerability requires physical access to the device via a USB stick.
- Record
EUVD-2023-54086- CVSS 3.1
- 6.8 Medium
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Updated
- 2026-11-03
GitHub AdvisoriesGHSA-866w-mhv5-886h
6.8
?A command injection vulnerability exists in Trane XL824, XL850, XL1050, and Pivot thermostats...
?A command injection vulnerability exists in Trane XL824, XL850, XL1050, and Pivot thermostats allowing an attacker to execute arbitrary commands as root using a specially crafted filename. The vulnerability requires physical access to the device via a USB stick.
- Record
GHSA-866w-mhv5-886h- CVSS 3.1
- 6.8 Medium
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-74, CWE-77
- Updated
- 2026-11-02
NVD
6.8
A command injection vulnerability exists in Trane XL824, XL850, XL1050, and Pivot thermostats allowing an attacker to execute arbitrary commands as root using a specially crafted filename. The vulnerability requires physical access to the device via a USB stick.
- Record
CVE-2023-4212- CVSS 3.1
- 6.8 Medium
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-74, CWE-77
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases, published | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2023-4212 is a medium vulnerability (CVSS 6.8) in Trane Technologies Pivot Thermostat, published August 22, 2023. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.33%, the 71st percentile. No source names a fixed version.
References
https//www.cisa.gov/news-events/ics-advisories/icsa-23-234-02
hub.tranetechnologies.com/docs/DOC-216377
trane.com/commercial/north-america/us/en/contact-us/locate-sales-offices.html
nvd.nist.gov/vuln/detail/CVE-2023-4212
cisa.gov/news-events/ics-advisories/icsa-23-234-02
github.com/advisories/GHSA-866w-mhv5-886h