Every CVE Search/ Get API key

CVE-2024-4708

mySCADA myPRO Use of Hard-coded Password

9.3 Critical

mySCADA myPRO

uses a hard-coded password which could allow an attacker to remotely execute code on the affected device.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

1.00%Up 1.0 points since Jul 3, 2024
90%50%10%1%

What each source reports

CVE List Score used 9.3

mySCADA myPRO Use of Hard-coded Password

mySCADA myPRO

uses a hard-coded password which could allow an attacker to remotely execute code on the affected device.

Record
CVE-2024-4708
CVSS 4.0
9.3 CriticalCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-259
Updated
2026-11-02
EUVDEUVD-2024-44305 9.3

mySCADA myPRO

uses a hard-coded password which could allow an attacker to remotely execute code on the affected device.

Record
EUVD-2024-44305
CVSS 4.0
9.3 CriticalCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Updated
2026-11-03
GitHub AdvisoriesGHSA-8w3c-2jv9-vpm4 9.3

mySCADA myPRO uses a hard-coded password which could allow an attacker to remotely execute code...

mySCADA myPRO

uses a hard-coded password which could allow an attacker to remotely execute code on the affected device.

Record
GHSA-8w3c-2jv9-vpm4
CVSS 4.0
9.3 CriticalCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-259, CWE-798
Updated
2026-11-02
NVD 9.3

mySCADA myPRO

uses a hard-coded password which could allow an attacker to remotely execute code on the affected device.

Record
CVE-2024-4708
CVSS 4.0
9.3 CriticalCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-259, CWE-798
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliases, publishedEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2024-4708 is a critical vulnerability (CVSS 9.3) in Myscada Mypro, published July 2, 2024. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.00%, the 62nd percentile. No source names a fixed version.

References

MoveEnter Open