CVE-2026-50609
Unauthorized Registry Modification Vulnerability in NitroSense and PredatorSense Software
A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. Insufficient access controls within a privileged Named Pipe service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, this could lead to privilege escalation or compromise of the affected system.
Attack profile
How easy it is to exploit
- Attack vector
- Local
- Complexity
- Low
- Privileges needed
- Low
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
CVE List Score used
7.4
Unauthorized Registry Modification Vulnerability in NitroSense and PredatorSense Software
A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. Insufficient access controls within a privileged Named Pipe service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, this could lead to privilege escalation or compromise of the affected system.
- Record
CVE-2026-50609- CVSS 4.0
- 7.4 High
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:U - Weakness
- CWE-284
- Updated
- 2026-11-02
EUVDEUVD-2026-81401
7.4
A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. Insufficient access controls within a privileged Named Pipe service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, this could lead to privilege escalation or compromise of the affected system.
- Record
EUVD-2026-81401- CVSS 4.0
- 7.4 High
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:U - Updated
- 2026-11-02
GitHub AdvisoriesGHSA-4m99-cchc-mf8w
7.4
A vulnerability has been identified in the Acer System Monitoring component included with...
A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. Insufficient access controls within a privileged Named Pipe service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, this could lead to privilege escalation or compromise of the affected system.
- Record
GHSA-4m99-cchc-mf8w- CVSS 4.0
- 7.4 High
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X - Weakness
- CWE-284
- Updated
- 2026-11-02
NVD
7.4
A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense. Insufficient access controls within a privileged Named Pipe service may allow an authenticated local user to perform unauthorized registry operations. In certain situations, this could lead to privilege escalation or compromise of the affected system.
- Record
CVE-2026-50609- CVSS 4.0
- 7.4 High
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X - Weakness
- CWE-284
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| first indexed | CVE List, EUVD, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2026-50609 is a high vulnerability (CVSS 7.4) in Acer System Monitoring, published September 17, 2026. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.13%, the 2nd percentile. No source names a fixed version.