Every CVESearch/Get API key

CVE-2015-2746

The network diagnostics tool (CommandLineServlet) in the Appliance Manager command line utility ...

6.5 MediumPublic exploit

CVE-2015-2746 is a medium vulnerability (CVSS 6.5) in Websense Triton, published March 26, 2015. Public exploit code exists. EPSS puts the chance of exploitation in the next 30 days at 25.4%, the 97th percentile. No source names a fixed version.

Severity
6.5 MediumCVSS 2.0, NVD
Exploit chance
25.4%EPSS, 97th percentile
Exploitation
None known1 public exploit
Fixed in
No fix listedNo source names one

Description

The network diagnostics tool (CommandLineServlet) in the Appliance Manager command line utility (CLU) in Websense TRITON 7.8.3 and V-Series appliances before 7.8.4 Hotfix 02 allows remote authenticated users to execute arbitrary commands via shell metacharacters in the "second" parameter of a command, as demonstrated by the Destination parameter in the ping command.

Exploit likelihood

25.4%Up 15.6 points since Feb 4, 2022
90%50%10%1%

Affected products

Public exploits

Links only. Every CVE stores no exploit code.

Public exploits
SourceLinkDate
Exploit-DBWebsense Appliance Manager - Command Injection2015-03-18

What each source reports

NVD Score used6.5

The network diagnostics tool (CommandLineServlet) in the Appliance Manager command line utility (CLU) in Websense TRITON 7.8.3 and V-Series appliances before 7.8.4 Hotfix 02 allows remote authenticated users to execute arbitrary commands via shell metacharacters in the "second" parameter of a command, as demonstrated by the Destination parameter in the ping command.

Record
CVE-2015-2746
CVSS 2.0
6.5 MediumAV:N/AC:L/Au:S/C:P/I:P/A:P
Weakness
CWE-77
Updated
2026-11-02
CVE ListNo score

The network diagnostics tool (CommandLineServlet) in the Appliance Manager command line utility (CLU) in Websense TRITON 7.8.3 and V-Series appliances before 7.8.4 Hotfix 02 allows remote authenticated users to execute arbitrary commands via shell metacharacters in the "second" parameter of a command, as demonstrated by the Destination parameter in the ping command.

Record
CVE-2015-2746
Updated
2026-11-02
EUVDEUVD-2015-2836No score

The network diagnostics tool (CommandLineServlet) in the Appliance Manager command line utility (CLU) in Websense TRITON 7.8.3 and V-Series appliances before 7.8.4 Hotfix 02 allows remote authenticated users to execute arbitrary commands via shell metacharacters in the "second" parameter of a command, as demonstrated by the Destination parameter in the ping command.

Record
EUVD-2015-2836
Updated
2026-11-03
GitHub AdvisoriesGHSA-86h5-7c4r-g3ghNo score

The network diagnostics tool (CommandLineServlet) in the Appliance Manager command line utility ...

The network diagnostics tool (CommandLineServlet) in the Appliance Manager command line utility (CLU) in Websense TRITON 7.8.3 and V-Series appliances before 7.8.4 Hotfix 02 allows remote authenticated users to execute arbitrary commands via shell metacharacters in the "second" parameter of a command, as demonstrated by the Destination parameter in the ping command.

Record
GHSA-86h5-7c4r-g3gh
Weakness
CWE-77
Updated
2026-11-02

History

History
RecordedChangedSources
facts
aliasesEUVD
first indexedCVE List, Exploit-DB, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

References

MoveEnter Open